Description
The Print Cartridge Shop LTMR08MFM for Schneider Electric Motor management controller TeSys T-940463 Product Description Schneider Electric LTMR08MFM Motor management controller TeSys T-940463 New NFP Qty : 1 Part No : LTMR08MFM Condition : New Manufactured By :Scneider Specifications:- LTMR08MFM Product picture View all Tesys T LTMR08MFM Product picture Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC LTMR08MFM Compare Environmental performance of the product Learn more Find a reseller Contact SalesContact supportSubscribe to the newsletter Main documents Product datasheet User guide Instruction sheet Catalogue Technical Drawing CAD file Environmental disclosure See all documents Compatible Software PSA101199 Product picture PSA101199 EcoStruxure Power Operation - Server, Unlimited Points PSWSANCZZSPEZZ Product picture PSWSANCZZSPEZZ Power Monitoring Expert Standard Edition BASE licence (incld 1… PSA101113 Product picture PSA101113 EcoStruxure Power Operation - Server, 1500 Points PSA101114 Product picture PSA101114 EcoStruxure Power Operation - Server, 5000 Points PSA101115 Product picture PSA101115 EcoStruxure Power Operation - Server, 15000 Points Description TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses Modbus as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Specifications Main range TeSys product name TeSys T device short name LTMR product or component type Motor controller device application Equipment monitoring and control measurement current 0.4…8 A [Us] rated supply voltage 100...240 V AC 50/60 Hz current consumption 8...62.8 mA supply voltage limits 93.5…264 V AC communication port protocol Modbus bus type Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs Complementary [Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 [Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1 associated fuse rating 4 A gG for output 0.5 A gG for control circuit protection type Reverse polarity protection Locked rotor Earth-leakage protection Thermal overload protection Phase failure Overload Thermal protection Power factor variation Load fluctuation Phase unbalance Overload (long time) network and machine diagnosis type Event recording Fault recording Waiting time after overload tripping Running hours counter/operating time Phase fault and earth fault trip counters Trip context information Starting current and time Motor control command recording Remaining operating time before overload tripping Trip history information logic input number 6 input current 3.1 mA at 100 V 7.5 mA at 240 V current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms maximum output switching frequency 2 Hz load current 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) maximum operating rate 1800 cyc/h contacts type and composition 1 NO + 1 NC fault signal 3 NO metering type Average current Iavg Temperature Earth-fault current Imbalance current Phase current I1, I2, I3 RMS measurement accuracy 5...15 % earth fault current internal measurement 1 % voltage (100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power overvoltage category III connection pitch 5.08 mm connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm pollution degree 3 electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 width 91 mm height 61 mm depth 122.5 mm net weight 0.53 kg web services Web server compatibility code LTMR Environment standards IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14 product certifications ABS KERI BV EAC CSA GL C-Tick ATEX UL RMRoS NOM CCC DNV RINA LROS (Lloyds register of shipping) protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 fire resistance 650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 ambient air temperature for operation -20…60 °C ambient air temperature for storage -40…80 °C operating altitude <= 2000 m without derating mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 IP degree of protection IP20 Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 10.0 cm Package 1 Width 13.6 cm Package 1 Length 7.2 cm Package 1 Weight 524.0 g Unit Type of Package 2 S02 Number of Units in Package 2 10 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.594 kg Contractual warranty Warranty 18 months Payment Policy We assure secured payment and accept payment through PayPal and all universally accepted credit cards. Shipping Policy We offer All Areas Shipping Australia Wide, extra charge for insured freight with tracking for this item. All despatched items are highly recommended to insure for their full value for peace of mind. If you win / order more than one item and ship together we will discount the shipping on the extra items. General shipping time is between one and three working days. Return Policy We offer a 30 days money back ploicy, if you are not satisfied with our products. © Copyright The Print Cartridge Shop | All Rights Reserved. Listing and template services provided by inkFrog